storage battery factory 12V100AH storage battery for solar

Category:
Description

 

Model Rated Voltage   (v) Capacity L W H TH Reference weight(Kg)
TB100-12  12   100 334mm 172mm 215mm 215mm 27

Product Features

Maintenance Simple

Made of flame retardant, super ABS shell, using polymer epoxy sealing technology, attractive appearance, firm structure, reliable seal without leakage.

Excellent Performance

  • Plate grid using special alloys, strict control of separator, the electrolyte and impurities of each step , extremely low self-discharge.
  • Plates, converge row,pole etc.using optimal design, the separator resistance is very low, so the battery internal resistance is low, good performance of high current discharge.
  • Using pure Germany technology, its low internal resistance, good performance of high rate discharge.
  • Adding special additives to positive and negative lead paste . High utilization of the active material, overcharge, over discharge acceptance ability is strong.
  • Using the unique combination of labyrinth pole seal structure (patented technology) and welding process, ensure sealed,safe and reliable.

Safe and Reliable

Accurately control of safety valve opening and closing valve pressure,not only release excessive gas caused by wrong operation or overcharge , but also prevent air outside or spark from entering the battery inside causing self-discharge or  bursting , high performance, long life.

Working Principle

  • Lead-acid batteriesproduce reaction in the charge-discharge process as below:

, Late period of charge, positive precipitates oxygen, negative precipitates hydrogen gas .

Technical Performance

Charge performance

  • Cycle using, the battery with constant current limiting charging, the charging voltage is 14.40V / pc, initial charge current is the same as float use.
  • Supplementary charge: If the battery after long-term storage prior to use, you need to add power.

Discharge Performance

  • Discharge characteristics: with the discharge capacity of the battery discharge current increases, it declines; on the contrary, the discharge capacity  increases; discharge capacity of the battery increases with temperature increasing, declines with temperature declines

Self-discharge performance 

  • Battery using a unique formula electrolyte additives , normal temperature storage 12 months, more than 90% capacity retention.
  • Battery storage for some time, the open-circuit voltage can be approximated by the remaining battery capacity.

Acceptance

Batteries sent to the user, such as in the following conditions may be accepted.

  • Battery casing, cover and terminal no physical damage, no leakage, climb acid phenomenon.
  • Open circuit voltage difference △u ≤04V / pc.

Installation

  • Batteries are charged before out of the factory, in the transport installation process to guard against short circuit.
  • Battery voltage is higher, in the installation and maintenance should use insulated tools to prevent electric shock.
  • Connecting cable as short as possible to prevent excessive pressure drop.
  • End connections in the installation and on-battery system, check the total voltage of  battery system and positive and negative, in order to ensure the correct installation.

We also have 12V7AH 12AH 24AH 38AH 50AH 65AH 80AH 100AH 120AH 150AH 200AH 250AH and 2V300AH-3000AH storage battery, please contact us for details